Three-phase protector / measuring apparatus RD 828T

Presented in casing for Standard DIN 35mm rail (EN 50 022), it is a compact device controlled by a 16 Bit microcomputer, highly stable due to the inclusion of a double state of process watchdog. It withstands permanent and transitory peak surges, as well as low voltage. It can protect multiple, single-phase or three-phase lines, of up to 63A.
It provides diverse measurements and protections programmable in value and delay :

  • Differential protection with very high speed cut-off
  • Protection against peak surge via very high speed physical cut-off
  • Protection against low voltage
  • Protection against over-intensity
  • True RMS and Peak Measurement of V, I, I ∆ n, W, VA, VarL, VarC, kWh, Etc.

Moreover, constant surveillance of the power input enables an Intelligent Automatic Reset (conditioned). In other words, it resets only on re-establishing normality in the supply. Certain models / versions have Remote Control input and output.

 

Three-phase protector / measuring apparatus (4 poles) With I. Differential
MODEL RD
VERSION 828T
True RMS Surge and Peak Surge Measurement 0V to 1000Vpk L1, L2, L3 independientes ·
True RMS Intensity and Peak Surge Measurement in autoscale 0A to 20Apk & 0A to 100Apk independent L1, L2, L3  
I Differential - True RMS and Peak Surge Measurement 0mA to 500mApk ·
Protection due to Peak Surge True RMS 245V to 275V & 20mS to 5Seg independent L1, L2, L3  
Protection due to Peak Surge 350Vpk to 400Vpk & 0.3mS to 5mS independent L1, L2, L3  
Protection due to True Low Voltage 175V to 200V & 20mS to 5Seg independent L1, L2, L3  
Protection due to Over-intensity True RMS 5A to 60A & 20mS to 10Segindependent L1, L2, L3  
Protection due to Peak Over-intensity (DISABLING) 7Apk to 84Apk & 0.3mS to 5mS independent L1, L2, L3  
Protection due to I. Differential True RMS 50mA to 300mA & 20mS to 160mS independent L1, L2, L3  
Protection due to Peak I. Differential 70mApk to 420mApk & 0.3mS to 5mS independent L1, L2, L3  
Protection due to I. Differential True RMS 5mA to 30mA & 20mS to 160mS independent L1, L2, L3 ·
Protection due to Peak I. Differential 7mApk to 42mApk & 0.3mS to 5mS independent L1, L2, L3 ·
Rearmes independientes programables I Differential From 0 to 10 Resets and from 3 to 240 min. each one  
Rearmes independientes programables Over-intensity  
Rearmes independientes programables Circuit breaker ·
Real Incremental Protection Test: Differential intensity test ·
Surge test V1  
Surge test V2  
Surge test V3  
Low voltage test V1  
Low voltage test V2  
Low voltage test V3  
Test sobre intensidad I1  
Test sobre intensidad I2  
Test sobre intensidad I3  
Self-testing of Differential + Toroidal Transformer sensor ·
Self-testing of outer cabling, internal electronic system ·
Chronological recorder of incidents and protections of all the alarms (Value, Tour, Minute, Day, Month, Year)  
Totaliser – Counter of cut-off time due to power failure  
Independent cut-off counters of all the alarms + accumulated total and historical total ·
Alarm register and their history (Maximum and minimum values) ·
Register of maximum measurements ·
Programmable Start-up delay  0 to 999 sec. ·
Manual Cut-off (Reset only with user key code) ·
Security settings (Programming of all the parameters only with user key code) ·
Average measurement displayed, programmable from 20 mS to 1000 mS ·
Change of user key code ·
Setting by default of Alarms (Value and Delay) ·
Automatic / Manual Display / Manual (Data rotation)  
Programmable Calendar Clock  
“Info” function (Information about the state of the alarm programming) ·
Acoustic and luminous indicator ·

 

 

 

 