Three-phase protector / measuring apparatus DOV 842RT

Presented in casing for Standard DIN 35mm rail (EN 50 022), it is a compact device controlled by a 16 Bit microcomputer, highly stable due to the inclusion of a double state of process watchdog. It withstands permanent and transitory peak surges, as well as low voltage. It can protect multiple, single-phase or three-phase lines, of up to 63A.
It provides diverse measurements and protections programmable in value and delay :

  • Differential protection with very high speed cut-off
  • Protection against peak surge via very high speed physical cut-off
  • Protection against low voltage
  • Protection against over-intensity
  • True RMS and Peak Measurement of V, I, I ∆ n, W, VA, VarL, VarC, kWh, Etc.

Moreover, constant surveillance of the power input enables an Intelligent Automatic Reset (conditioned). In other words, it resets only on re-establishing normality in the supply. Certain models / versions have Remote Control input and output.

 

Three-phase protector / measuring apparatus (4 poles) With I. Differential
MODEL DOV
VERSION 842RT
True RMS Surge and Peak Surge Measurement 0V to 1000Vpk L1, L2, L3 independientes ·
True RMS Intensity and Peak Surge Measurement in autoscale 0A to 20Apk & 0A to 100Apk independent L1, L2, L3  
I Differential - True RMS and Peak Surge Measurement 0mA to 500mApk ·
Protection due to Peak Surge True RMS 245V to 275V & 20mS to 5Seg independent L1, L2, L3 ·
Protection due to Peak Surge 350Vpk to 400Vpk & 0.3mS to 5mS independent L1, L2, L3 ·
Protection due to True Low Voltage 175V to 200V & 20mS to 5Seg independent L1, L2, L3 ·
Protection due to Over-intensity True RMS 5A to 60A & 20mS to 10Segindependent L1, L2, L3  
Protection due to Peak Over-intensity (DISABLING) 7Apk to 84Apk & 0.3mS to 5mS independent L1, L2, L3  
Protection due to I. Differential True RMS 50mA to 300mA & 20mS to 160mS independent L1, L2, L3  
Protection due to Peak I. Differential 70mApk to 420mApk & 0.3mS to 5mS independent L1, L2, L3  
Protection due to I. Differential True RMS 5mA to 30mA & 20mS to 160mS independent L1, L2, L3 ·
Protection due to Peak I. Differential 7mApk to 42mApk & 0.3mS to 5mS independent L1, L2, L3 ·
Rearmes independientes programables I Differential From 0 to 10 Resets and from 3 to 240 min. each one ·
Rearmes independientes programables Over-intensity  
Rearmes independientes programables Circuit breaker ·
Real Incremental Protection Test: Differential intensity test ·
Surge test V1 ·
Surge test V2 ·
Surge test V3 ·
Low voltage test V1 ·
Low voltage test V2 ·
Low voltage test V3 ·
Test sobre intensidad I1  
Test sobre intensidad I2  
Test sobre intensidad I3  
Self-testing of Differential + Toroidal Transformer sensor ·
Self-testing of outer cabling, internal electronic system ·
Chronological recorder of incidents and protections of all the alarms (Value, Tour, Minute, Day, Month, Year) ·
Totaliser – Counter of cut-off time due to power failure ·
Independent cut-off counters of all the alarms + accumulated total and historical total ·
Alarm register and their history (Maximum and minimum values) ·
Register of maximum measurements ·
Programmable Start-up delay  0 to 999 sec. ·
Manual Cut-off (Reset only with user key code) ·
Security settings (Programming of all the parameters only with user key code) ·
Average measurement displayed, programmable from 20 mS to 1000 mS ·
Change of user key code ·
Setting by default of Alarms (Value and Delay) ·
Automatic / Manual Display / Manual (Data rotation) ·
Programmable Calendar Clock  
“Info” function (Information about the state of the alarm programming) ·
Acoustic and luminous indicator ·

 

 

 

 